TECHNICAL PARTICULARS OF COMPOSITE RAILWAY TRACTION INSULATORS
 
 
 
     
 
Sl.no Parameter Unit Stayarm Insulator Bracket Insulator 9-tonne Insulator
1 Shed Diameter
mm
185/145
185/145
185/145
2 Unit Spacing
mm
489
555
540
3 Creepage Distance
mm
1050
1050
1050
4 Arcover Distance
mm
390
390
390
5 Electro-Mechanical Min. Failing Load
kgfm
200
200
210
6 Coupling Designation
kgf
7000 7000 11000
7 Pf-Wet Withstand Voltage
kV
125
125
125
8 Pf-Dry Withstand Voltage
kV
100 100 100
9 DRY-Lightning Impulse Withstand Voltage positive
kVp
240 240 240
10 DRY-Lightning Impulse Withstand Voltage negative
kVp
260 260 260
11 Visible Discharge Test Voltage
kV
35 35 35
12 Weight of Unit (Approx)
kg
4.4
5.0
5.4
 
     
 
  1. Specific creepage distance from 16 mm / kV to 40 mm / kV
2. Length ranges from 285 mm to 4080 mm
3. Specified mechanical loads from
 
  a. 45 KN to 120 kN for 33 kV to 132 kV.
b. 70 KN to 160 kN for 220 kV.
c. 120 KN to 160 kN for 400 kV.
  4. For specific requirement, contact: CBU / Marketing, Malleshwaram, Bangalore....560012